FR200 with prismatic PMMA enclosure

Version
with single battery emergency light element | insulation class I

FR200 damp-proof diffuser luminaire for ceiling surface mounting, suspended mounting or mounting to a rail | direct extremely wide distribution with ceiling illumination**; with prismatic cover | with ECG or LLCG, additionally with single battery emergency light element | housing of glass-fibre reinforced polyester, grey; cover of PMMA

Protection rating: IP65
Insulation class: I
Protection symbol: F

** direct distribution via supplementary reflector

Electrical

Luminaire for operation on 'normal mains' or via the integral self-contained supply | wired ready for connection, with 4-pole connection terminal (3-pole for normal mains with switched phase* + single pole for additional unswitched phase* for emergency light element), max. 2.5mm² | cable entry suitable for cables or conduits with Ø= 8.5..13.5mm, with twin entry grommet (accessory) for 2 cables Ø= 8.4..12mm | with ECG, with single battery emergency light element* (for 1h operation) and with LED (for optical self-test functioning control of battery***) | luminaire suitable for through-wiring (with special wiring sets) within luminaires

Rated voltage= 220..240V / AC 50..60Hz

* the switched phase (terminal >L1<) and the unswitched phase (terminal >L2<) must have the same phase angle | the emergency battery is charged over the unswitched phase and the luminaire is informed of the operational condition (normal or emergency):

  • non-switched phase in operation: ---> normal operation (luminaire operation via mains, normal on/off switching)
  • non-switched phase missing: ---> emergency operation (via battery) | luminaire is switched on even when luminaire was switched off in normal operation

    *** LED signals:
    Green LED: battery connected and charged
    Green blinking LED: battery being charged
    Red blinking LED: battery not connected or defect
    Yellow blinking LED: automatic discharging / charging of battery

    Emergency operation with reduced lumen output:
    Lumen output phi=12% (T26 lamping, 58W)
    With twin-lamp luminaires: operation with one lamp

    permissible ambient temperature for luminaire with single battery emergency light element:
    0°C to 25°C

Lamps Socket Wt. (kg) Order No.
ECG, F, with emergency light element, nominal service life 1h
1x T26 58W G13 4.2 5LS32271EA04
2x T26 58W G13 4.7 5LS32272EA04
Accessories
Article Wt. (kg) Order No.
specular reflector, aluminium, highly specular, direct symmetric distribution, for 1x T26 58W 0.2 5LS32201ES
specular reflector, aluminium, highly specular, direct symmetric distribution, for 2x T26 58W 0.2 5LS32202ES